99视频精品全部在线观看下载,精品999久久久久久,欧美日韩国产精品久久久久久久,亚洲欧美日韩亚洲欧美日韩

咨詢熱線

18621916738

當前位置:首頁   >  產(chǎn)品中心  >  西門子PLC模塊  >  西門子S7-300PLC模塊  >  西門子PLC模塊CPU314C-2PN/DP

西門子PLC模塊CPU314C-2PN/DP

簡要描述:西門子PLC模塊CPU314C-2PN/DP,西門子S7-300CPU314C-2PN/DP,SIMATIC S7-300, CPU 314C-2PN/DP 緊湊型CPU帶有192 KB工作存儲區(qū), 24 數(shù)字量輸入/16 數(shù)字量輸出, 4模擬量輸入, 2模擬量輸出, 1 PT100, 4 快速計數(shù)器 (60 KHZ), 1. 接口 MPI/DP 12MBIT/S, 2. 接口以太網(wǎng) PROFIN

  • 產(chǎn)品型號:
  • 廠商性質(zhì):代理商
  • 更新時間:2017-09-17
  • 訪  問  量:1264

詳細介紹

西門子PLC模塊CPU314C-2PN/DP,西門子S7-300CPU314C-2PN/DP,西門子CPU314C-2PN/DP,CPU314C-2PN/DP,西門子S7-300CPU314C-2PN/DP可編程控制器

訂貨號:6ES7314-6EH04-0AB0

SIMATIC S7-300, CPU 314C-2PN/DP 緊湊型CPU帶有192 KB工作存儲區(qū), 24 數(shù)字量輸入/16 數(shù)字量輸出, 4模擬量輸入, 2模擬量輸出, 1 PT100, 4 快速計數(shù)器 (60 KHZ), 1. 接口 MPI/DP 12MBIT/S, 2. 接口以太網(wǎng) PROFINET, 含 2個 PORT SWITCH, 集成 24V DC 電源, FRONT C

德國* 現(xiàn)貨銷售 質(zhì)保一年 歡迎詢價

SIEMENS上海翰粵自動化系統(tǒng)有限公司

 

上海翰粵公司在經(jīng)營活動中精益求精,具備如下業(yè)務優(yōu)勢:
SIEMENS 可編程控制器
  1、 SIMATIC S7 系列PLC:S7-200、S7-1200、S7-300、S7-400、ET-200
  2、 邏輯控制模塊 LOGO!230RC、230RCO、230RCL、24RC、24RCL等
  3、 SITOP直流電源 24V DC 1.3A、2.5A、3A、5A、10A、20A、40A可并聯(lián).

4、HMI 觸摸屏TD200 TD400C K-TP OP177 TP177,MP277 MP377,
SIEMENS 交、直流傳動裝置
  1、 交流變頻器 MICROMASTER系列:MM420、MM430、MM440、G110、G120.  

  MIDASTER系列:MDV
  2、全數(shù)字直流調(diào)速裝置 6RA23、6RA24、6RA28、6RA70、6SE70系列

SIEMENS 數(shù)控 伺服

SINUMERIK:801、802S 、802D、802D SL、810D、840D、611U、S120

系統(tǒng)及伺報電機,力矩電機,直線電機,伺服驅(qū)動等備件銷售。

西門子PLC模塊CPU314C-2PN/DP,西門子S7-300CPU314C-2PN/DP, 概述

  • 帶集成的數(shù)字量和模擬量輸入/輸出的緊湊型 CPU
  • 對二進制和浮點數(shù)運算具有較高的處理能力
  • 用于通過 PROFIBUS 和 PROFINET 進行分布式 I/O 連接。
  • 組合 MPI/PROFIBUS DP-主/從接口
  • 用于 2 端口交換機的 PROFINET 接口
  • PROFINET I/O 控制器,用于在PROFINET上運行分布式I/O
  • PROFINET I-Device,用于連接作為智能 PROFINET 設備、帶 SIMATIC 或第三方 PROFINET I/O 控制器的 CPU
  • 在PROFINET上實現(xiàn)基于組件的自動化(CBA)
  • PROFINET 代理,用于基于組件的自動化(CBA)中的 PROFIBUS DP 智能設備
  • 集成 Web 服務器,帶有創(chuàng)建用戶定義的 Web 站點的選項
  • 經(jīng)由 PROFIBUS 的等時同步模式

CPU 運行需要 SIMATIC 微存儲卡(MMC)。

,西門子S7-300CPU314C-2PN/DP 應用領域

CPU 314C-2 DP 是緊湊型 CPU,適合安裝在分布式結構中。通過其擴展工作存儲器,該緊湊型CPU也適用于中等規(guī)模的應用。集成的數(shù)字量和模擬量輸入和輸出可與過程信號直接連接。集成的 的PROFIBUS DP 主站/從站以及 PROFINET IO 控制器/I-設備接口,用于 PROFIBUS 和 PROFINET 的分布式連接。這使得 CPU 314C-2 PN/DP 可作為進行快速處理的分布式單元使用,也可作為 PROFIBUS 和 PROFINET 系統(tǒng)中具有低端現(xiàn)場總線系統(tǒng)的上位控制器。

集成技術工程的其他用途包括:

  • 計數(shù)
  • 頻率測量
  • 周期測量
  • 脈寬調(diào)制
  • PID 控制
  • 定位控制

,西門子S7-300CPU314C-2PN/DP

CPU 314C-2 DP 安裝有:

  • 微處理器;
    每條二進制指令執(zhí)行時間約60ns,每條浮點數(shù)運行指令約0.59µs.
  • 擴展存儲器;
    與執(zhí)行相關的程序段的 192 KB 高速 RAM(相當于約 64 K 指令)可以為用戶程序提供足夠的空間;
    SIMATIC 微型存儲卡(zui大 8 MB)作為程序的裝載存儲器,還允許將項目(包括符號和注釋)存儲在 CPU 中。
  • 靈活的擴展能力
    多達 31 個模塊,(4排結構)
  • 多點接口(MPI);
    集成的 MPI 接口zui多可以同時建立與 S7-300/400 或編程設備、PC、OP 的 12 條連接。在這些連接中,總要分別為 PG 和 OP 各保留一個連接。通過“全局數(shù)據(jù)通訊”,MPI可以用來建立zui多16個CPU組成的簡單網(wǎng)絡。
  • PROFIBUS DP 接口:
    帶有 PROFIBUS DP 主/從接口的 CPU 314C-2 DP 可以用來建立高速、易用的分布式自動化系統(tǒng)。 對用戶來說,分布式I/O單元可作為一個集中式單元來處理(相同的組態(tài)、編址和編程).
  • 以太網(wǎng)接口;
    CPU 314C-2 PN/DP 的第 2 個內(nèi)置接口是一個基于以太網(wǎng) TCP/IP 的 PROFINET 接口,帶有雙端口交換機。
    它支持下列協(xié)議:
    • S7通訊用于在SIMATIC控制器間進行數(shù)據(jù)交換;
    • 用于通過 STEP 7 編程、調(diào)試和診斷的編程器/OP通訊
    • 與HMI和SCADA連接的PG/OP通訊;
    • 通過 PROFINET 進行的開放式 TCP/IP、UDP 和 ISO-on-TCP (RFC1006) 通訊
    • SIMATIC NET OPC-Server用于與其它控制器以及CPU自帶的I/O設備進行通訊
  • 內(nèi)置輸入/輸出;
    24路數(shù)字量輸入(所有輸入都可用作中斷處理)和16路數(shù)字量輸出,以及5個模擬量輸入和2個模擬量輸出,使得CPU 314C-2 DP是一款*的控制器。

,西門子S7-300CPU314C-2PN/DP 設計

  • 口令保護;
    用戶程序使用密碼保護,可防止非法訪問。
  • 塊加密
    相關功能 (FC) 和 功能塊 (FB) 可以加密的方式存儲于 CPU 以保護專門知識應用。
  • 診斷緩沖;
    zui后500個故障和中斷事件保存在該緩沖區(qū)中,供診斷使用。 其中,保留zui后 100 個條目
  • 免維護的數(shù)據(jù)后備;
    如果發(fā)生斷電,則可通過 CPU 將所有數(shù)據(jù)(zui多達 64 KB)自動寫入到 SIMATIC 微型存儲卡(MMC 卡)上,且將在再次通電時保持不變。

可參數(shù)化的特性

可以使用 STEP 7 對 S7 的組態(tài)、屬性以及CPU的響應進行參數(shù)設置:

  • 概要:
    定義名稱、系統(tǒng)號和位置號
  • 啟動;
    定義 CPU 的啟動特性和監(jiān)視時間
  • 同步循環(huán)中斷;
    設置 IO 系統(tǒng)編號、過程映像分區(qū)編號和延時
  • 循環(huán)/時鐘存儲器;
    定義zui大的掃循環(huán)描時間和負載設置時鐘存儲器地址
  • 記憶性;
    定義具有保持功能的存儲位、計數(shù)器、定時器和數(shù)據(jù)塊的數(shù)量
  • 日時鐘中斷
    設定起始日期、起始時間和間隔周期
  • 周期中斷;
    周期設定
  • 系統(tǒng)診斷;
    定義診斷消息的處理和范圍。
  • 時鐘;
    設定 AS 內(nèi)或 MPI 上的同步方式
  • 防護等級;
    說明程序和數(shù)據(jù)訪問授權。
  • 通訊;
    保留連接源
  • Web;
    CPU 的 Web 服務器設置
  • MPI/PROFIBUS-DP 接口:
    設置接口類型。定義節(jié)點地址。對操作模式進行參數(shù)化,并組態(tài)使用 PROFIBUS DP 時的傳輸區(qū)對時間同步進行參數(shù)化
  • PROFINET 接口;
    地址設定。對 PROFINET 屬性、智能設備功能、PROFINET 上的同步類型、使用 NTP 步驟的時間同步、介質(zhì)冗余和 KeepAlive 功能進行參數(shù)化。參數(shù)化端口 1 和端口 2
  • 數(shù)字量輸入/輸出
    地址設定,輸入繼電器和過程中斷
  • 模擬輸入/輸出
    設定地址
    輸入的情況下:設定溫度單元,測量種類,測量范圍,以及接口頻率
    輸出的情況下:設定輸出類別和輸出范圍
  • 集成功能“計數(shù)器” 
    設定地址,以及 “連續(xù)計數(shù)”“單次計數(shù)”“周期計數(shù)”“頻率測量”和“脈寬調(diào)制”模式下的參數(shù)分配
  • 集成功能“定位器” 
    設定地址,“數(shù)字輸出定位”和“模擬輸出定位”參數(shù)
  • 集成功能“規(guī)則”

顯示功能與信息功能

  • 狀態(tài)和故障指示;
    LED 指示硬件、編程、定時或 I/O 故障以及操作狀態(tài)(如 RUN、STOP 和 Start-up)。
  • 測試功能;
    可使用編程器顯示程序執(zhí)行過程中的信號狀態(tài),可以不通過用戶程序而修改過程變量,以及輸出堆棧內(nèi)容。
  • 信息功能;
    您可以使用編程器以純文本的形式獲取 CPU 存儲容量和操作模式、工作存儲器和裝載存儲器的當前利用率以及當前循環(huán)時間和診斷緩沖區(qū)內(nèi)容的相關信息。

集成的通訊功能

  • 編程器/OP 通訊
  • 全局數(shù)據(jù)通訊
  • S7 基本通訊
  • S7 通訊
  • 路由
  • 數(shù)據(jù)記錄路徑
  • PROFIBUS DP 主站/從站
  • 通過 TCP/IP、ISO-on-TCP 和 UDP 進行開放式通訊
  • PROFINET IO 控制器
  • PROFINET 智能設備
  • PROFINET CBA(基于組件的自動化)
  • Web 服務器

集成功能

  • 計數(shù)器;
    4 個計數(shù)器(zui高 60 kHz),具有獨立方向的比較器,可直接連接到 24V 增量編碼器。
  • 4通道頻率測量;
    允許進行頻率測量(高達 60 kHz),例如,測量軸速或吞吐量(每個測量周期內(nèi)的件數(shù))。
  • 周期測量
    用于獲取并處理計數(shù)脈沖,頻率zui高為 1 KHz
  • 脈寬調(diào)制;
    4個輸出可直接連接控制閥、執(zhí)行器、開關設備、加熱裝置等,例如采樣頻率為 2.5 kHz。 可設置周期長度并可在運行時修改占空比。
  • 定位控制
    集成在操作系統(tǒng)中的SFB可通過2路數(shù)字量輸出或1個模擬量輸出對1個軸進行定位控制。
  • 報警輸入(所有數(shù)字量輸入);
    報警輸入可以檢測過程事件,并在zui短的時間內(nèi)觸發(fā)響應。

,西門子S7-300CPU314C-2PN/DP 技術規(guī)格

 

6ES7 314-6EH04-0AB0

General information

 

Hardware product version

01

Firmware version

V3.3

Supply voltage

 

24 V DC

Yes

permissible range, lower limit (DC)

19.2 V

permissible range, upper limit (DC)

28.8 V

Mains buffering

 

  • Mains/voltage failure stored energy time

5 ms

  • Repeat rate, min.

1 s

Digital inputs

 

  • Load voltage L+

 

    • Rated value (DC)

24 V

    • Reverse polarity protection

Yes

Digital outputs

 

  • Load voltage L+

 

    • Rated value (DC)

24 V

    • Reverse polarity protection

No

Input current

 

Current consumption (rated value)

850 mA

Current consumption (in no-load operation), typ.

190 mA

Inrush current, typ.

5 A

I²t

0.7 A²·s

from supply voltage L+, max.

850 mA

Digital inputs

 

  • from load voltage L+ (without load), max.

80 mA

Digital outputs

 

  • from load voltage L+, max.

50 mA

Power losses

 

Power loss, typ.

14 W

Memory

 

Type of memory

other

Work memory

 

  • integrated

192 kbyte

  • expandable

No

  • Size of retentive memory for retentive data blocks

64 kbyte

Load memory

 

  • pluggable (MMC)

Yes

  • pluggable (MMC), max.

8 Mbyte

  • Data management on MMC (after last programming), min.

10 a

Backup

 

  • present

Yes

  • without battery

Yes; Program and data

CPU processing times

 

for bit operations, typ.

0.06 µs

for word operations, typ.

0.12 µs

for fixed point arithmetic, typ.

0.16 µs

for floating point arithmetic, typ.

0.59 µs

CPU-blocks

 

Number of blocks (total)

1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.

DB

 

  • Number, max.

1 024

  • Size, max.

64 kbyte

FB

 

  • Number, max.

1 024

  • Size, max.

64 kbyte

FC

 

  • Number, max.

1 024; Number range: 0 to 7999

  • Size, max.

64 kbyte

OB

 

  • Description

see instruction list

  • Size, max.

64 kbyte

  • Number of free cycle OBs

1

  • Number of time alarm OBs

1

  • Number of delay alarm OBs

2

  • Number of time interrupt OBs

4

  • Number of process alarm OBs

1

  • Number of DPV1 alarm OBs

3; OB 55, 56, 57

  • Number isochronous mode OBs

1; OB 61; only for PROFINET

  • Number of startup OBs

1

  • Number of asynchronous error OBs

6

  • Number of synchronous error OBs

2

Nesting depth

 

  • per priority class

16

  • additional within an error OB

4

Counters, timers and their retentivity

 

S7 counter

 

  • Number

256

  • Retentivity

 

    • adjustable

Yes

    • lower limit

0

    • upper limit

255

    • preset

Z 0 to Z 7

  • Counting range

 

    • adjustable

Yes

    • lower limit

0

    • upper limit

999

IEC counter

 

  • present

Yes

  • Type

SFB

  • Number

Unlimited (limited only by RAM capacity)

S7 times

 

  • Number

256

  • Retentivity

 

    • adjustable

Yes

    • lower limit

0

    • upper limit

255

    • preset

No retentivity

  • Time range

 

    • lower limit

10 ms

    • upper limit

9 990 s

IEC timer

 

  • present

Yes

  • Type

SFB

  • Number

Unlimited (limited only by RAM capacity)

Data areas and their retentivity

 

retentive data area, total

All, max. 64 KB

Flag

 

  • Number, max.

256 byte

  • Retentivity available

Yes; MB 0 to MB 255

  • Retentivity preset

MB 0 to MB 15

  • Number of clock memories

8; 1 memory byte

Data blocks

 

  • Number, max.

1 024; Number range: 1 to 16000

  • Size, max.

64 kbyte

  • Retentivity adjustable

Yes; via non-retain property on DB

  • Retentivity preset

Yes

Local data

 

  • per priority class, max.

32 kbyte; Max. 2048 bytes per block

Address area

 

I/O address area

 

  • Inputs

2 048 byte

  • Outputs

2 048 byte

  • of which, distributed

 

    • Inputs

2 003 byte

    • Outputs

2 010 byte

Process image

 

  • Inputs

2 048 byte

  • Outputs

2 048 byte

  • Inputs, adjustable

2 048 byte

  • Outputs, adjustable

2 048 byte

  • Inputs, default

256 byte

  • Outputs, default

256 byte

  • Default addresses of the integrated channels

 

    • Digital inputs

136.0 to 138.7

    • Digital outputs

136.0 to 137.7

    • Analog inputs

800 to 809

    • Analog outputs

800 to 803

Subprocess images

 

  • Number of subprocess images, max.

1; With PROFINET IO, the length of the user data is limited to 1600 bytes

Digital channels

 

  • Inputs

16 048

  • Outputs

16 096

  • Inputs, of which central

1 016

  • Outputs, of which central

1 008

Analog channels

 

  • Inputs

1 006

  • Outputs

1 007

  • Inputs, of which central

253

  • Outputs, of which central

250

Hardware configuration

 

Expansion devices, max.

3

Number of DP masters

 

  • integrated

1

  • via CP

4

Number of operable FMs and CPs (recommended)

 

  • FM

8

  • CP, point-to-point

8

  • CP, LAN

10

Rack

 

  • Racks, max.

4

  • Modules per rack, max.

8; In rack 3 max. 7

Time of day

 

Clock

 

  • Hardware clock (real-time clock)

Yes

  • battery-backed and synchronizable

Yes

  • Deviation per day, max.

10 s; Typ.: 2 s

  • Backup time

6 wk; At 40 °C ambient temperature

  • Behavior of the clock following POWER-ON

Clock continues running after POWER OFF

  • Behavior of the clock following expiry of backup period

Clock continues to run with the time at which the power failure occurred

Operating hours counter

 

  • Number

1

  • Number/Number range

0

  • Range of values

0 to 2^31 hours (when using SFC 101)

  • Granularity

1 hour

  • retentive

Yes; Must be restarted at each restart

Clock synchronization

 

  • supported

Yes

  • to MPI, master

Yes

  • to MPI, slave

Yes

  • to DP, master

Yes; With DP slave only slave clock

  • to DP, slave

Yes

  • in AS, master

Yes

  • in AS, slave

Yes

  • on Ethernet via NTP

Yes; as client

Digital inputs

 

Number of digital inputs

24

  • of which, inputs usable for technological functions

16

integrated channels (DI)

24

Input characteristic curve in accordance with IEC 61131, type 1

Yes

Number of simultaneously controllable inputs

 

  • horizontal installation

 

    • up to 40 °C, max.

24

    • up to 60 °C, max.

12

  • vertical installation

 

    • up to 40 °C, max.

12

Input voltage

 

  • Rated value, DC

24 V

  • for signal "0"

-3 to +5 V

  • for signal "1"

15 to 30 V

Input current

 

  • for signal "1", typ.

8 mA

Input delay (for rated value of input voltage)

 

  • for standard inputs

 

    • Parameterizable

Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.)

    • Rated value

3 ms

  • for counter/technological functions

 

    • at "0" to "1", max.

8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency

Cable length

 

  • Cable length, shielded, max.

1 000 m

  • Cable length unshielded, max.

600 m

  • Technological functions

 

    • shielded, max.

50 m; at maximum count frequency

    • Unshielded, max.

not allowed

  • Standard DI

 

    • shielded, max.

1 000 m

    • Unshielded, max.

600 m

Digital outputs

 

Number of digital outputs

16

  • of which high-speed outputs

4; Notice: You cannot connect the fast outputs of your CPU in parallel

integrated channels (DO)

16

Short-circuit protection

Yes; Clocked electronically

  • Response threshold, typ.

1 A

Limitation of inductive shutdown voltage to

L+ (-48 V)

Controlling a digital input

Yes

Switching capacity of the outputs

 

  • Lamp load, max.

5 W

Load resistance range

 

  • lower limit

48 Ω

  • upper limit

4 kΩ

Output voltage

 

  • for signal "1", min.

L+ (-0.8 V)

Output current

 

  • for signal "1" rated value

500 mA

  • for signal "1" permissible range, min.

5 mA

  • for signal "1" permissible range, max.

0.6 A

  • for signal "1" minimum load current

5 mA

  • for signal "0" residual current, max.

0.5 mA

Parallel switching of 2 outputs

 

  • for increased power

No

  • for redundant control of a load

Yes

Switching frequency

 

  • with resistive load, max.

100 Hz

  • with inductive load, max.

0.5 Hz

  • on lamp load, max.

100 Hz

  • of the pulse outputs, with resistive load, max.

2.5 kHz

Aggregate current of outputs (per group)

 

  • horizontal installation

 

    • up to 40 °C, max.

3 A

    • up to 60 °C, max.

2 A

  • vertical installation

 

    • up to 40 °C, max.

2 A

Cable length

 

  • Cable length, shielded, max.

1 000 m

  • Cable length unshielded, max.

600 m

Analog inputs

 

Number of analog inputs

5

Integrated channels (AI)

5; 4 x current/voltage, 1 x resistance

Number of analog inputs for voltage/current measurement

4

Number of analog inputs for resistance/resistance thermometer measurement

1

permissible input frequency for current input (destruction limit), max.

5 V

permissible input voltage for voltage input (destruction limit), max.

30 V; Permanent

permissible input current for voltage input (destruction limit), max.

0.5 mA

permissible input current for current input (destruction limit), max.

50 mA; Permanent

Technical unit for temperature measurement adjustable

Yes; Degrees Celsius / degrees Fahrenheit / Kelvin

Input ranges

 

  • Voltage

Yes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ

  • Current

Yes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω

  • Resistance thermometer

Yes; Pt 100 / 10 MΩ

  • Resistance

Yes; 0 Ω to 600 Ω / 10 MΩ

Input ranges (rated values), voltages

 

  • 0 to +10 V

Yes

  • Input resistance (0 to 10 V)

100 kΩ

Input ranges (rated values), currents

 

  • 0 to 20 mA

Yes

  • Input resistance (0 to 20 mA)

100 Ω

  • -20 to +20 mA

Yes

  • Input resistance (-20 to +20 mA)

100 Ω

  • 4 to 20 mA

Yes

  • Input resistance (4 to 20 mA)

100 Ω

Input ranges (rated values), resistance thermometers

 

  • Pt 100

Yes

  • Input resistance (Pt 100)

10 MΩ

Input ranges (rated values), resistors

 

  • No-Load voltage, typ.

3.3 V

  • Measured current, typ.

1,25 mA

  • 0 to 600 ohms

Yes

  • Input resistance (0 to 600 ohms)

10 MΩ

Thermocouple (TC)

 

  • Temperature compensation

 

    • Parameterizable

No

Characteristic linearization

 

  • Parameterizable

Yes; by software

    • for resistance thermometer

Pt 100

Cable length

 

  • Cable length, shielded, max.

100 m

Analog outputs

 

Number of analog outputs

2

Integrated channels (AO)

2

Voltage output, short-circuit protection

Yes

Voltage output, short-circuit current, max.

55 mA

Current output, no-load voltage, max.

14 V

Output ranges, voltage

 

  • 0 to 10 V

Yes

  • -10 to +10 V

Yes

Output ranges, current

 

  • 0 to 20 mA

Yes

  • -20 to +20 mA

Yes

  • 4 to 20 mA

Yes

Connection of actuators

 

  • for voltage output two-wire connection

Yes; Without compensation of the line resistances

  • for voltage output four-wire connection

No

  • for current output two-wire connection

Yes

Load impedance (in rated range of output)

 

  • with voltage outputs, min.

1 kΩ

  • with voltage outputs, capacitive load, max.

0.1 µF

  • with current outputs, max.

300 Ω

  • with current outputs, inductive load, max.

0.1 mH

Destruction limits against externally applied voltages and currents

 

  • Voltages at the outputs towards MANA

16 V; Permanent

  • Current, max.

50 mA; Permanent

Cable length

 

  • Cable length, shielded, max.

200 m

Analog value creation

 

Measurement principle

Actual value encryption (successive approximation)

Integrations and conversion time/resolution per channel

 

  • Resolution with overrange (bit including sign), max.

12 bit

  • Integration time, parameterizable

Yes; 16.6 / 20 ms

  • permissible input frequency, max.

400 Hz

  • Interference voltage suppression for interference frequency f1 in Hz

60 / 50 Hz

  • Conversion time (per channel)

1 ms

  • Time constant of the input filter

0.38 ms

  • Basic execution time of the module (all channels released)

1 ms

Settling time

 

  • for resistive load

0.6 ms

  • for capacitive load

1 ms

  • for inductive load

0.5 ms

Encoder

 

Connection of signal encoders

 

  • for voltage measurement

Yes

  • for current measurement as 2-wire transducer

Yes; with external supply

  • for current measurement as 4-wire transducer

Yes

  • for resistance measurement with two-wire connection

Yes; Without compensation of the line resistances

  • for resistance measurement with three-wire connection

No

  • for resistance measurement with four-wire connection

No

Connectable encoders

 

  • 2-wire sensor

Yes

    • Permissible quiescent current (2-wire sensor), max.

1.5 mA

Errors/accuracies

 

Temperature error (relative to input range), (+/-)

0.006 %/K

Crosstalk between the inputs, min.

60 dB

Repeat accuracy in steady state at 25 °C (relative to input area), (+/-)

0.06 %

Output ripple (based on output area, bandwidth 0 to 50 kHz), (+/-)

0.1 %

Linearity error (relative to output range), (+/-)

0.15 %

Temperature error (relative to output range), (+/-)

0.01 %/K

Crosstalk between the outputs, min.

60 dB

Repeat accuracy in steady state at 25 °C (relative to output area), (+/-)

0.06 %

Operational limit in overall temperature range

 

  • Voltage, relative to input area, (+/-)

1 %

  • Current, relative to input area, (+/-)

1 %

  • Resistance, relative to input area, (+/-)

1 %

  • Voltage, relative to output area, (+/-)

1 %

  • Current, relative to output area, (+/-)

1 %

Basic error limit (operational limit at 25 °C)

 

  • Voltage, relative to input area, (+/-)

0.8 %; Linearity error +/- 0.06 %

  • Current, relative to input area, (+/-)

0.8 %; Linearity error +/- 0.06 %

  • Resistance, relative to input area, (+/-)

0.8 %; Linearity error +/- 0.2%

  • Resistance thermometer, relative to input area, (+/-)

0.8 %

  • Voltage, relative to output area, (+/-)

0.8 %

  • Current, relative to output area, (+/-)

0.8 %

Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency

 

  • Series mode interference (peak value of interference < rated value of input range), min.

30 dB

  • Common mode interference, min.

40 dB

Interfaces

 

Number of USB interfaces

0

Number of parallel interfaces

0

Number of 20 mA interfaces (TTY)

0

Number of RS 232 interfaces

0

Number of RS 422 interfaces

0

Number of other interfaces

1; Ethernet, 2-port switch, 2*RJ45

1st interface

 

Interface type

Integrated RS 485 interface

Physics

RS 485

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

200 mA

Functionality

 

  • MPI

Yes

  • DP master

Yes

  • DP slave

Yes

  • Point-to-point connection

No

MPI

 

  • Transmission rate, max.

12 Mbit/s

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

Yes

    • S7 basic communication

Yes

    • S7 communication

Yes

    • S7 communication, as client

No; but via CP and loadable FB

    • S7 communication, as server

Yes

DP master

 

  • Transmission rate, max.

12 Mbit/s

  • Number of DP slaves, max.

124

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

No

    • S7 basic communication

Yes; I blocks only

    • S7 communication

Yes

    • S7 communication, as client

No

    • S7 communication, as server

Yes

    • Equidistance mode support

Yes

    • Isochronous mode

No

    • SYNC/FREEZE

Yes

    • Activation/deactivation of DP slaves

Yes

    • Number of DP slaves that can be simultaneously activated/deactivated, max.

8

    • Direct data exchange (slave-to-slave communication)

Yes; As subscriber

    • DPV1

Yes

  • Address area

 

    • Inputs, max.

2 kbyte

    • Outputs, max.

2 kbyte

  • User data per DP slave

 

    • Inputs, max.

244 byte

    • Outputs, max.

244 byte

DP slave

 

  • Transmission rate, max.

12 Mbit/s

  • Automatic baud rate search

Yes; only with passive interface

  • Address area, max.

32

  • User data per address area, max.

32 byte

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes; Only with active interface

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication

Yes

    • S7 communication, as client

No

    • S7 communication, as server

Yes; Connection configured on one side only

    • Direct data exchange (slave-to-slave communication)

Yes

    • DPV1

No

  • Transfer memory

 

    • Inputs

244 byte

    • Outputs

244 byte

2nd interface

 

Interface type

PROFINET

Physics

Ethernet RJ45

Isolated

Yes

Integrated switch

Yes

Number of ports

2

Automatic detection of transmission speed

Yes; 10/100 Mbit/s

Autonegotiation

Yes

Autocrossing

Yes

Change of IP address at runtime, supported

Yes

Media redundancy

 

  • supported

Yes

  • Switchover time on line break, typically

200 ms; PROFINET MRP

  • Number of stations in the ring, max.

50

Functionality

 

  • MPI

No

  • DP master

No

  • DP slave

No

  • PROFINET IO Controller

Yes; Also simultaneously with IO-Device functionality

  • PROFINET IO Device

Yes; Also simultaneously with IO Controller functionality

  • PROFINET CBA

Yes

  • Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • Web server

Yes

    • Number of HTTP clients

5

PROFINET IO Controller

 

  • Transmission rate, max.

100 Mbit/s

  • Number of connectable IO devices, max.

128

  • Max. number of connectable IO devices for RT

128

    • of which in line, max.

128

  • Number of IO devices with IRT and the option "high flexibility"

128

    • of which in line, max.

61

  • Number of IO Devices with IRT and the option "high performance", max.

64

    • of which in line, max.

64

  • IRT, supported

Yes

  • Shared device, supported

Yes

  • Prioritized startup supported

Yes

    • Number of IO Devices, max.

32

  • Activation/deactivation of IO Devices

Yes

    • Maximum number of IO devices that can be activated/deactivated at the same time.

8

  • IO Devices changing during operation (partner ports), supported

Yes

    • Max. number of IO devices per tool

8

  • Device replacement without swap medium

Yes

  • Send cycles

250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)

  • Updating time

250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, Technical Data" for more details)

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • S7 communication

Yes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32

    • Isochronous mode

Yes; OB 61

    • Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

  • Address area

 

    • Inputs, max.

2 kbyte

    • Outputs, max.

2 kbyte

    • User data consistency, max.

1 024 byte

PROFINET IO Device

 

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • S7 communication

Yes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32

    • Isochronous mode

No

    • Open IE communication

Yes; Via TCP/IP, ISO on TCP, and UDP

    • IRT

Yes

    • PROFIenergy, supported

Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device

    • Shared device

Yes

    • Number of IO controllers with shared device, max.

2

  • Transfer memory

 

    • Inputs, max.

1 440 byte; Per IO Controller with shared device

    • Outputs, max.

1 440 byte; Per IO Controller with shared device

  • Submodules

 

    • Number, max.

64

    • User data per submodule, max.

1 024 byte

PROFINET CBA

 

  • acyclic transmission

Yes

  • Cyclic transmission

Yes

Open IE communication

 

  • Open IE communication, supported

Yes

  • Number of connections, max.

8

  • Local port numbers used at the system end

0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535

  • Keep-alive function, supported

Yes

Isochronous mode

 

Isochronous operation (application synchronized up to terminal)

Yes; For PROFINET only

Communication functions

 

PG/OP communication

Yes

Data record routing

Yes

Global data communication

 

  • supported

Yes

  • Number of GD loops, max.

8

  • Number of GD packets, max.

8

  • Number of GD packets, transmitter, max.

8

  • Number of GD packets, receiver, max.

8

  • Size of GD packets, max.

22 byte

  • Size of GD packet (of which consistent), max.

22 byte

S7 basic communication

 

  • supported

Yes

  • User data per job, max.

76 byte

  • User data per job (of which consistent), max.

76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)

S7 communication

 

  • supported

Yes

  • as server

Yes

  • As client

Yes

  • User data per job, max.

See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)

S5-compatible communication

 

  • supported

Yes; via CP and loadable FC

Open IE communication

 

  • TCP/IP

Yes; via integrated PROFINET interface and loadable FBs

    • Number of connections, max.

8

    • Data length for connection type 01H, max.

1 460 byte

    • Data length for connection type 11H, max.

32 768 byte

    • Several passive connections per port, supported

Yes

  • ISO-on-TCP (RFC1006)

Yes; via integrated PROFINET interface and loadable FBs

    • Number of connections, max.

8

    • Data length, max.

32 768 byte

  • UDP

Yes; via integrated PROFINET interface and loadable FBs

    • Number of connections, max.

8

    • Data length, max.

1 472 byte

Web server

 

  • supported

Yes

  • Number of HTTP clients

5

  • User-defined websites

Yes

PROFINET CBA (at set setpoint communication load)

 

  • Setpoint for the CPU communication load

50 %

  • Number of remote interconnection partners

32

  • Number of functions, master/slave

30

  • Total of all Master/Slave connections

1 000

  • Data length of all incoming connections master/slave, max.

4 000 byte

  • Data length of all outgoing connections master/slave, max.

4 000 byte

  • Number of device-internal and PROFIBUS interconnections

500

  • Data length of device-internal und PROFIBUS interconnections, max.

4 000 byte

  • Data length per connection, max.

1 400 byte

  • Remote interconnections with acyclic transmission

 

    • Sampling frequency: Sampling time, min.

500 ms

    • Number of incoming interconnections

100

    • Number of outgoing interconnections

100

    • Data length of all incoming interconnections, max.

2 000 byte

    • Data length of all outgoing interconnections, max.

2 000 byte

    • Data length per connection, max.

1 400 byte

  • Remote interconnections with cyclic transmission

 

    • Transmission frequency: Transmission interval, min.

10 ms

    • Number of incoming interconnections

200

    • Number of outgoing interconnections

200

    • Data length of all incoming interconnections, max.

2 000 byte

    • Data length of all outgoing interconnections, max.

2 000 byte

    • Data length per connection, max.

450 byte

  • HMI variables via PROFINET (acyclic)

 

    • Number of stations that can log on for HMI variables (PN OPC/iMap)

3; 2x PN OPC/1x iMap

    • HMI variable updating

500 ms

    • Number of HMI variables

200

    • Data length of all HMI variables, max.

2 000 byte

  • PROFIBUS proxy functionality

 

    • supported

Yes

    • Number of linked PROFIBUS devices

16

    • Data length per connection, max.

240 byte; Slave-dependent

Number of connections

 

  • overall

12

  • usable for PG communication

11

    • reserved for PG communication

1

    • Adjustable for PG communication, min.

1

    • Adjustable for PG communication, max.

11

  • usable for OP communication

11

    • reserved for OP communication

1

    • adjustable for OP communication, min.

1

    • adjustable for OP communication, max.

11

  • usable for S7 basic communication

8

    • Reserved for S7 basic communication

0

    • adjustable for S7 basic communication, min.

0

    • adjustable for S7 basic communication, max.

8

  • usable for S7 communication

10

    • reserved for S7 communication

0

    • Adjustable for S7 communication, min.

0

    • Adjustable for S7 communication, max.

10

  • Max. total number of instances

32

  • usable for routing

X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.

S7 message functions

 

Number of login stations for message functions, max.

12; Depending on the configured connections for PG/OP and S7 basic communication

Process diagnostic messages

Yes

simultaneously active Alarm-S blocks, max.

300

Test commissioning functions

 

Status block

Yes; Up to 2 simultaneously

Single step

Yes

Number of breakpoints

4

Status/control

 

  • Status/control variable

Yes

  • Variables

Inputs, outputs, memory bits, DB, times, counters

  • Number of variables, max.

30

  • of which status variables, max.

30

  • of which control variables, max.

14

Forcing

 

  • Forcing

Yes

  • Force, variables

Inputs, outputs

  • Number of variables, max.

10

Diagnostic buffer

 

  • present

Yes

  • Number of entries, max.

500

    • adjustable

No

    • Of which powerfail-proof

100; Only the last 100 entries are retained

  • Number of entries readable in RUN, max.

499

    • adjustable

Yes; From 10 to 499

    • preset

10

Service data

 

  • Can be read out

Yes

Interrupts/diagnostics/status information

 

Diagnostics indication LED

 

  • Status indicator digital output (green)

Yes

  • Status indicator digital input (green)

Yes

Integrated Functions

 

Number of counters

4; See "Technological Functions" manual

Counter frequency (counter) max.

60 kHz

Frequency measurement

Yes

Number of frequency meters

4; up to 60 kHz (see "Technological Functions" manual)

controlled positioning

Yes

Integrated function blocks (closed-loop control)

Yes; PID controller (see "Technological Functions" manual)

PID controller

Yes

Number of pulse outputs

4; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual)

Limit frequency (pulse)

2.5 kHz

Galvanic isolation

 

Galvanic isolation digital inputs

 

  • Galvanic isolation digital inputs

Yes

  • between the channels

No

  • between the channels and the backplane bus

Yes

Galvanic isolation digital outputs

 

  • Galvanic isolation digital outputs

Yes

  • between the channels

Yes

  • between the channels, in groups of

8

  • between the channels and the backplane bus

Yes

Galvanic isolation analog inputs

 

  • Galvanic isolation analog inputs

Yes

  • between the channels

No

  • between the channels and the backplane bus

Yes

Galvanic isolation analog outputs

 

  • Galvanic isolation analog outputs

Yes

  • between the channels

No

  • between the channels and the backplane bus

Yes

Permissible potential difference

 

between inputs and MANA (UCM)

8 V DC

between MANA and M internally (UISO)

75 VDC / 60 VAC

Ambient conditions

 

Operating temperature

 

  • Min.

0 °C

  • max.

60 °C

Configuration

 

Configuration software

 

  • STEP 7

Yes; V5.5 or higher

programming

 

  • Command set

see instruction list

  • Nesting levels

8

  • System functions (SFC)

see instruction list

  • System function blocks (SFB)

see instruction list

  • Programming language

 

    • LAD

Yes

    • FBD

Yes

    • STL

Yes

    • SCL

Yes

    • CFC

Yes

    • GRAPH

Yes

    • HiGraph®

Yes

Know-how protection

 

  • User program protection/password protection

Yes

  • Block encryption

Yes; With S7 block Privacy

Dimensions

 

Width

120 mm

Height

125 mm

Depth

130 mm

Weights

 

Weight, approx.

730 g

 

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數(shù)字),如:三加四=7

聯(lián)系我們

上海翰粵自動化系統(tǒng)有限公司 公司地址:上海市松江區(qū)思賢路2399弄137號   技術支持:化工儀器網(wǎng)
  • 聯(lián)系人:黃政武
  • QQ:76868608
  • 公司傳真:021-57657276
  • 郵箱:76868608@qq.com

掃一掃 更多精彩

微信二維碼

網(wǎng)站二維碼

同德县| 余姚市| 新乡县| 青岛市| 砀山县| 嫩江县| 日土县| 留坝县| 高邮市| 迭部县| 河源市| 耿马| 阳原县| 郯城县| 克什克腾旗| 张掖市| 建宁县| 翼城县| 万年县| 开鲁县| 华蓥市| 南靖县| 聂拉木县| 松江区| 南木林县| 贵德县| 沾化县| 巩义市| 花莲市| 临泽县| 荆州市| 会宁县| 连江县| 邵武市| 错那县| 宜川县| 云安县| 禄劝| 黄梅县| 潼南县| 若尔盖县|